Kapabilitas Transformer Aplikasi Khusus

 

image 1
Tegangan Custom & Rating Saiki
image 2
Dhuwur Thermal & Short{0}}Circuit Tahan
image 3
Selaras karo Standar IEC, IEEE, CSA
image
Harmonic & Overload -Desain Tahan

 

 

Jinis Penawaran Transformers Khusus SCOTECH

 

Minangka produsen trafo khusus sing berpengalaman, kita ngrancang lan ngasilake macem-macem trafo kanggo non-standar,

syarat khusus-tugas lan{1}}aplikasi. Ing ngisor iki minangka jinis utama trafo khusus sing diwenehake

proyek industri lan sistem daya global.

 

Transformator Rectifier Kab

Trafo rectifier dirancang khusus kanggo nyuplai daya menyang sistem rectifier, ngowahi daya AC dadi daya DC kanggo proses industri sing mbutuhake output saiki lan stabil. Iki digunakake akeh ing industri pangolahan elektrokimia, pabrik metalurgi, lan sistem sepur.
• Daya Rated:Nganti 100 MVA
• Rated High Voltage:Nganti 132 kV

Trafo Traksi

Trafo traksi minangka komponen kritis ing sistem pasokan tenaga sepur lan metro, nyedhiyakake daya sing stabil lan dipercaya ing fluktuasi beban sing terus-terusan lan kahanan operasi sing atos. Utamane digunakake ing transportasi listrik lan sistem transit rel.
• Daya Rated:Nganti 100 MVA
• Rated High Voltage:Nganti 132 kV

Transformator Tungku

Trafo tungku nyetel voltase AC (step-munggah/mudhun-) kanggo sistem tungku: unit kapasitas gedhe -khusus kanggo peleburan logam industri (contone, baja, aluminium elektrolitik), tahan arus abot, busur -tekanan mekanik/termal sing diakibatake, lan nggunakake rod karbon minangka elektroda.
• Daya Rated:Nganti 150 MVA
• Rated High Voltage:Nganti 35 kV

Transformator Pembumian Kab

Transformer earthing digunakake kanggo nyedhiyakake titik netral ing sistem tenaga sing ora ana, mbisakake grounding sing efektif lan mbatesi arus kesalahan kanggo proteksi sistem. Utamane digunakake ing gardu listrik, sistem tenaga industri, kilang, lan lapangan liyane.
• Daya Rated:Nganti 5 MVA
• Rated High Voltage:Nganti 35 kV

Entuk Penawaran Khusus Transformer Khusus Dina iki

Dhiskusi karo ahli Scotech supaya trafo direkayasa miturut kabutuhan sampeyan.

Kauntungan Transformator Khusus

1. Reliabilitas sing ora bisa ditandingi ing Kahanan Ekstrem

2. Kustomisasi jero kanggo fungsi tartamtu

3. Enhanced System Efficiency & Protection

4. Kekuwatan Mekanik & Struktural Unggul

5. Keahlian Aplikasi, Ora Mung Manufaktur

6. Total Lifecycle Dhukungan

Hubungi kita
Special Transformer Advantage
 

Aplikasi Khas Transformers Tipe Khusus Kita

 

Trafo khusus kita digunakake digunakake ing proyek sing trafo standar ora bisa ketemu teknis utawa

syarat operasional.

 

Industrial Electrochemical & EV Charging Power

Elektrokimia Industri &
Daya Pengisian EV

Penting kanggo operasi elektrolisis, elektroplating, lan metalurgi, nyedhiyakake konversi daya DC sing-efisiensi dhuwur kanggo peleburan, drive industri abot, lan sistem pangisian daya ultra{1}}cepet banget kendaraan listrik.

Metal Smelting and Thermal Processing

Peleburan Logam lan Thermal
Ngolah

Peralatan daya inti kanggo tungku busur lan sistem pemanasan, mbisakake kontrol suhu sing tepat lan kemampuan kakehan ing metalurgi lan perawatan panas.

Rail Electrification Systems

Elektrifikasi Rel
Sistem

Nyedhiyakake daya traksi sing stabil kanggo-rel kacepetan dhuwur, metro, lan lokomotif, njamin operasi tahan getaran- lan sirkuit -singkat-singkat.

Power System Safety Management

Manajemen Keamanan Sistem Daya

Nyedhiyakake grounding netral lan watesan saiki kesalahan ing tanduran energi sing bisa dianyari, pusat data, lan jaringan industri kanggo keamanan sing luwih apik.

Critical Energy Infrastructure

Energi Kritis
Infrastruktur

Ndhukung integrasi energi sing bisa dianyari, mesin abot, lan instalasi khusus kanthi kinerja kasar ing kahanan sing ekstrim.

Marine & Offshore Power

Marine & Offshore
daya

Dibangun kanggo panggunaan maritim sing atos ing kapal lan platform lepas pantai. Tahan karat-, tahan geter-, lan disertifikasi -laut kanggo operasi kritis.

 

 

Pengalaman Proyek Terbukti ing Transformers Tujuan Khusus

 

Kita nggawe kustom-trafo penyearah, trafo traksi, trafo tungku, lan trafo grounding

khusus kanggo nuntut aplikasi industri lan sarana.

 

6 MVA Railway Transformers-22 / 1,22 kV|Afrika Kidul 2023
6 MVA Railway Transformers-22 / 1,22 kV|Afrika Kidul 2023
Negara: Afrika Kidul 2024
Kapasitas: 6 MVA
Tegangan: 22/2 * 1,22 + 1,22 kV
Fitur: galvanis panas
3635 kVA Transformer Kanthi Rectifier-22 / 0,462 kV|Afrika Kidul 2022
3635 kVA Transformer Kanthi Rectifier-22 / 0,462 kV|Afrika Kidul 2022
Negara: Afrika Kidul 2022
Kapasitas: 2×(3635/2562-2562)kVA
Tegangan: 22/0.462 kV
Fitur: karo OLTC
5 MVA Railway Traksi Transformer-132 / 1,22 kV|Afrika Kidul 2025
5 MVA Railway Traksi Transformer-132 / 1,22 kV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5 MVA
Tegangan: 132/2*1.22+1.22kV
Fitur: karo nduwurke tumpukan tersier
5 MVA Railway Transformer-44 / 6,6 kV|Afrika Kidul 2025
5 MVA Railway Transformer-44 / 6,6 kV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5000 kVA
Tegangan: 44/6.6 kV
Fitur: karo panas -dip galvanis radiator
5 MVA Traksi Daya Transformer-22 / 6,6 kV|Afrika Kidul 2025
5 MVA Traksi Daya Transformer-22 / 6,6 kV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5000 kVA
Tegangan: 22/6.6 kV
Fitur: karo panas -dip galvanis radiator
370 kVA Grounding A Transformer-22 / 0,11 kV|Afrika Kidul 2024
370 kVA Grounding A Transformer-22 / 0,11 kV|Afrika Kidul 2024
Negara: Afrika Kidul 2024
Kapasitas: 370 kVA
Tegangan: 22/0.11 kV
Fitur: karo CT
3000 KVA IEC 60076 Power Transformers-88/11 KV|Afrika Kidul 2025
3000 KVA IEC 60076 Power Transformers-88/11 KV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 3000 kVA
Tegangan: 88/11 kV
Fitur: Low -kotak kabel metu sisih voltase
5 MVA Transformers Kanggo Sepur Sets-88/2*1.22+2.36 KV|Afrika Kidul 2025
5 MVA Transformers Kanggo Sepur Sets-88/2*1.22+2.36 KV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5000 kVA
Tegangan: 88/2*1.22+2.36 kV
Fitur: Tegangan tambahan: 2,36 kV
5 Transformers traksi MVA-132 / 1.22 KV|Afrika Kidul 2025
5 Transformers traksi MVA-132 / 1.22 KV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5000 kVA
Tegangan: 132/2*1.22+0.635 kV
Fitur: tegangan gulung tersier: 150kVA, 0.635kV
5.05 Transformers Sepur MVA-132/2*1.22+2.36 KV|Afrika Kidul 2025
5.05 Transformers Sepur MVA-132/2*1.22+2.36 KV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5050 kVA
Tegangan: 132/2*1.22+2.36 kV
Fitur: karo panas -dip galvanis radiator
5 MVA Model Railway Transformer-66 / 1.22 KV|Afrika Kidul 2025
5 MVA Model Railway Transformer-66 / 1.22 KV|Afrika Kidul 2025
Negara: Afrika Kidul 2025
Kapasitas: 5000 kVA
Tegangan: 66/1.22 kV
Fitur: karo panas -dip galvanis radiator

 

 

 

Produsen Transformer Khusus sing Terbukti Sampeyan Bisa Ngandelake

Desain sing disesuaikan

Kita bisa ngrancang trafo miturut paramèter listrik, karakteristik beban, lingkungan instalasi lan rincian liyane sing diwenehake. Iki njamin produk pungkasan nyukupi syarat lingkungan khusus sampeyan.

One{0}}Layanan mandeg

Kita nawakake layanan siji-mandeg sing nyakup konsultasi, penawaran, manufaktur, instalasi, komisioning, latihan lan layanan sawise{1}}sales.

Kontrol kualitas sing ketat

Saka nglereni inti lan nduwurke tumpukan kanggo perakitan lan testing, kabeh proses produksi wis rampung ing pabrik kita dhewe. Iki ngidini kita njamin kualitas produk rampung sing konsisten.

Tes Komprehensif Sadurunge Pangiriman

Saben trafo khusus ngalami tes rutin, tes jinis lan tes khusus -aplikasi sadurunge dikirim. Kita nyedhiyakake laporan tes sing rinci kanggo verifikasi kinerja produk lan nyuda risiko sadurunge instalasi.

 

 

 

Kemampuan Manufaktur, Pengujian & Pangiriman Proyek sing Terbukti

 
  • Referensi Proyek & Instalasi Situs
  • Ing -Proses Pabrikan ing omah
  • Pengujian & Verifikasi Kualitas
  • Packing, Pengiriman & Logistik
  • Railway Traction Transformer Project (6 MVA, 88 / 1.22 kV) – South Africa

    Proyek Transformer Traksi Railway (6 MVA, 88 / 1.22 kV) - Afrika Kidul

    Electric Furnace Transformer Project (120 MVA, 34.5 kV) – Iran

    Proyek Transformator Tungku Listrik (120 MVA, 34,5 kV) - Iran

    Earthing Transformer project (6900kVA 22kV)-Australia

    Proyek Earthing Transformer (6900kVA 22kV)-Australia

    Rectifier Transformer project(100 MVA 220 KV)-China

    Proyek Transformer Rectifier(100 MVA 220 KV)-China

    Autotransformer project (8MVA 33/33kV)-South Africa

    Proyek autotransformer (8MVA 33/33kV)-Afrika Kidul

    Traction Transformer(5MVA 88/1.22kV)- South Africa

    Traction Transformer(5MVA 88/1.22kV)- Afrika Kidul

  • 1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
  • 1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
  • 100 MVA 220 kV Rectifier Transformer Shipping

    100 MVA 220 kV Rectifier Transformer Shipping

    Traction Transformer 6000kVA 22/1.22kV-South Africa

    Traksi Trafo 6000kVA 22/1.22kV-Afrika Kidul

    Traction Transformer 5000kVA 132/1.22kV-South Africa

    Traksi Trafo 5000kVA 132/1.22kV-Afrika Kidul

    Autotransformer 8MVA 33/33kV-South Africa

    Autotransformer 8MVA 33/33kV-Afrika Kidul

    Traction Transformer 5000kVA 22/6.6kV-South Africa

    Traksi Trafo 5000kVA 22/6.6kV-Afrika Kidul

    Furnace Transformer 45 MVA 34.5 kV -Turkey

    Trafo Tungku 45 MVA 34,5 kV -Turki

 

 

 

FAQ

 

P: Industri apa sing nggunakake trafo khusus?

A: Trafo khusus SCOTECH digunakake akeh ing macem-macem industri, kalebu galangan kapal, pertambangan, sistem energi terbarukan, produksi baja, manufaktur kimia, lan metalurgi.

P: Apa sampeyan bisa ngrancang trafo khusus miturut syarat proyek kita?

A: Nggih. Kabeh trafo khusus kita direkayasa adhedhasar tingkat voltase, karakteristik beban, kahanan instalasi, lan standar sing ditrapake.

P: Apa sampeyan ndhukung proyek luar negeri lan kontraktor EPC?

A: Nggih. Kita duwe pengalaman ndhukung proyek EPC internasional kanthi dokumentasi, pengujian, lan logistik.

P: Informasi apa sing sampeyan butuhake kanggo menehi penawaran?

A: Tegangan, kapasitas, aplikasi, lingkungan instalasi, lan standar sing ditrapake.

P: Apa trafo khusus sampeyan -digawe khusus utawa produk standar?

A: Kabeh trafo khusus dirancang -selaras karo syarat teknis pelanggan. Desain standar uga bisa diowahi kanggo nyukupi aplikasi tartamtu.

P: Apa sampeyan ndhukung kustomisasi lengkap?

A: Ya, kita ndhukung desain khusus 100%, kalebu voltase, arus, daya, frekuensi, ukuran, cara pemasangan, metode pendinginan, lan syarat kanggo lingkungan aplikasi khusus.

P: Apa sampeyan duwe pengalaman babagan pasokan-jangka panjang utawa proyek-?

A: Nggih. Kita duwe pengalaman ekstensif ing -suplai jangka panjang lan solusi trafo basis proyek-kanggo pelanggan internasional.

 

 

 

Blog sing gegandhengan

 

 

 

image

Entuk Kutipan babagan Transformers Aplikasi Khusus

 
 

 

 

Jiangshan Scotech Electrical Co., Ltd minangka salah sawijining produsen lan pemasok trafo khusus ing China. Sugeng rawuh sampeyan tuku trafo khusus -efisien sing didol ing kene saka pabrik kita. Yen sampeyan duwe pitakon babagan kutipan utawa diagram, please aran gratis kanggo email kita.